The VoIP adapter with multiple FXS ports allows you to connect several analog phones and register them on SIP accounts. Before configuring the adapter, you must obtain SIP registration information from the PBX server.
This article applies to the VOIP adapter with multiple FXS ports including the following model.
| Model |
G504 |
G508 |
FGW4148-16S |
FGW4148-32S |
FGW4148-48S |
|
Ports FXS |
4 |
8 |
16 |
32 |
48 |
Step 1. Physical connection
1. Connect the G508 WAN port to the Router/Switch to access the Internet, connect the LAN port to a computer with an Ethernet cable, connect a PHONE port to the analog phone.

Step 2. Log in to the management page
Open a browser and enter the LAN IP address of the adapter 192.168.1.1 in the address bar, a login page appears as shown below, the default username and password are admin. Then click Connect.

Step 3. Register on the PBX server
Register a single FXS port
Go to SIP Account > FXS Settings, select a port, enable the Port Activation option, enter the proxy server, proxy port, transport, display name, phone number, account and password, then click Save & Apply at the bottom of the page.


Record multiple FXS ports
Go to SIP Account > Account, enter the start port number, end port number, display name, phone number, account, password, and step length (extension number interval), then click Set, the registration information for all ports is automatically filled in. click on Save at the bottom of the page.
Go to SIP Account > FXS Settings, enable Batch Settings, select the Start Port and End Port, enable the Port Enable option, set the proxy server, proxy port and transport, click Save & Apply at the bottom of the page.

Upon successful registration on the PBX server, the adapter’s PHONE LED turns solid green, and the SIP FXS account status shows Registered. The analog phone can then make outbound calls or receive inbound calls.