Power redundancy for uninterrupted service during power outages

In the past, the exchange office typically supplied power to the fire panel or emergency telephone, but in POTS replacement, the ATA, router or LTE modem must be powered individually. A device that consumes more power adds complexity and more problems in the event of a power outage.

De nombreuses solutions sur le marché utilisent une mini-UPS (via le port DC) comme redondance d’alimentation. Mais ces solutions ne offrent généralement pas la capacité de vérifier l’état de la batterie ou de la gérer à distance, alors que ces fonctions sont cruciales pour une exploitation à long terme.

Flyingvoice's complete POTS replacement series with internal battery continue to operate when DC power is cut off, with Flyingvoice hardware running uninterrupted thanks to the internal battery. When DC power returns to normal, the Flyingvoice hardware recharges the internal battery, ensuring continuous operation during a power outage.

The PR08-Pro supports a 65 W external PD battery connection; you can choose from different battery capacities based on the actual use of your system. When the main DC power is lost, the PR08‑Pro automatically switches to the external battery to keep the entire system running. When DC power is restored, it recharges the battery. It supports the PD 3.0 protocol, giving you more flexibility in battery choice.

The PR08‑Pro is an 8‑FXS ATA gateway that can provide power to other devices in your POTS Replacement system. It is equipped with a dual‑output PoE WAN port and a 4‑pin Molex Micro‑Fit 3.0™ DC output. This allows you to connect a router or 4G modem that does not support power redundancy; using Flyingvoice hardware, any device can be turned into a redundant power device.

In the event of prolonged and continuous operation, the device will inevitably malfunction, which can lead to device failure and make it unresponsive. The power cycle allows you to schedule a daily/weekly/monthly task to restart the PR08‑Pro or the external device powered by the PR08 to eliminate potential factors that could lead to system failure. You can also run a command to perform the power cycle via the cloud management platform to clear errors on your 4G router or modem.

05

More reliable equipment

Thanks to a low‑power design, Flyingvoice now launches a new compact device—PR12—which can support up to 24 hours of redundancy in POTS replacement. This small device integrates a 4G modem and a full ATA function, is equipped with an internal battery, and supports dual power: PoE input and DC input.

PR12

If you are looking for reliable hardware for unstable scenarios, this is what you are looking for.

In addition to the Flyingvoice PR08‑Pro and PR12, Flyingvoice will continue to launch more devices that originally supported power redundancy to adapt to different

solution.

Let’s discuss your project

Describe your requirements. Our team can help you select and plan your FlyingVoice solution.

✉
WhatsAppCall usRequest a quote