The VoIP adapter with multiple FXS ports allows you to connect multiple analog phones and register to the SIP accounts. Before configuring the adapter, you need to get the SIP registration information from the PBX server.
تنطبق هذه المقالة على محول VOIP مع عدة منافذ FXS بما في ذلك النموذج التالي.
| نموذج |
G504 |
G508 |
FGW4148-16S |
FGW4148-32S |
FGW4148-48S |
|
منافذ FXS |
4 |
8 |
16 |
32 |
48 |
الخطوة 1. الاتصال المادي
1. Connect the G508’s WAN port to the external/port R to access the Internet, connect the LAN port to computer using an Ethernet cable, and connect one of the PHONE ports to the analog phone.

الخطوة 2. تسجيل الدخول إلى صفحة الإدارة
Open a browser and type the local IP address of the switch 192.168.1.1 in the address bar; the login page will appear as shown below, with the default username and password both admin. Then click Log In.

الخطوة 3. التسجيل إلى خادم PBX
Register a single FXS port
Go to SIP Account > FXS Settings, select a port, enable the option Enable port, enter the proxy server, proxy port, transport, display name, phone number, account and password, then click Save and Apply at the bottom of the page.


Register multiple FXS ports
Go to SIP account > حساب, أدخل رقم المنفذ البداية، رقم المنفذ النهاية، الاسم المعروض، رقم الهاتف، الحساب، كلمة المرور وطول الخطوة (فاصل أرقام الامتداد)، ثم اضغط ضبط, يتم تعبئة معلومات التسجيل لجميع المنافذ تلقائيًا. انقر على حفظ في أسفل الصفحة.
Go to SIP account > FXS settings, enable Batch settings, select Start port and End port, enable the Port Enable option, set Proxy Server, Proxy Port and Transport, then click Save & Apply at the bottom of the page.

Upon successful registration with the PBX server, the PHONE light on the switch will flash green, and the FXS SIP account status will show as registered. The analog phone can make outbound calls or receive inbound calls.