Overview

POTS lines have been the main communication means for fire alarm systems for decades. But the demand for new POTS lines has decreased, the decision to end the technology was made. In 2019, the Federal Communications Commission (FCC) POTS line tolerance order 19-72A1 marked the end of life for traditional analog POTS line systems. While most commercial enterprises have migrated to VoIP or wireless for their voice telephony, many still rely on POTS lines for their fire alarm system.

For many years, Ademco Contact ID protocol has been the most widely used protocol that allows alarm systems to communicate with central stations. When an alarm is triggered, the alarm panel captures the telephone line and sends alarm signals to the central stations.

As technology evolves, these copper lines disappear and the alternative solution will be VoIP.

However, fully replacing original terminals with digital terminals will cost a significant budget and will increase the risk of business interruption. It is wiser to leave the fire alarm panel untouched and simply upgrade the communication lines. Switching to a wireless “line” to replace the “old copper line” is the simple solution that avoids problems.

Why can VoIP not work directly with fire alarm systems?

Most commercial fire alarm panels have two POTS replacement lines connected to them. Each panel has a central station transmitter that uses POTS lines to send an alarm signal to central stations when an alarm is triggered.

Unfortunately, when the POTS lines are replaced by VoIP, alarm signals can become unrecognizable to central stations. Because VoIP converts analog signals into digital signals, the way VoIP compresses and decompresses signals can significantly affect the attempted message. Monitoring stations almost always stop receiving signals from the fire alarm panel. This is in fact a common problem we have to face.

Une autre préoccupation est la redondance d’alimentation. Lorsque vous perdez l’alimentation électrique, tout appareil sans batterie de secours devient inutilisable. Les systèmes d’alarme incendie classiques disposent de leur propre batterie de secours, mais les systèmes VoIP standards n’en ont pas. Il est donc indispensable d’intégrer une batterie de secours à notre solution.

Now Flyingvoice provides a turnkey solution for POTS replacement in the fire alarm system.

First, we provide POTS enclosure which includes industrial LTE router for Internet access, external battery for battery redundancy, and ATA gateway to properly manage the original alarm signal.

Associated with our cloud service to improve alarm communication, delivery quality is guaranteed. The complete solution will comply with NFPA 72 Code (National Fire Alarm and Signaling Code).

Provision lines and configurations to ATA gateway, no change required on the alarm panel, simply connect the copper wire from RJ31x connector to the ATA gateway phone sockets, then the alarm system will work as usual.

For more details, please refer to flyingvoice.com