POTS lines were the primary means of connecting to fire alarm systems for decades. However, the decline in demand for new POTS lines led to the decision to phase out the technology. In 2019, the Federal Communications Commission (FCC) issued the POTS 19-72A1 order announcing the end of life for traditional analog POTS lines. While most commercial companies have shifted to VoIP or wireless for their voice calls, many still rely on POTS lines for fire alarm systems.
For several years, Ademco Contact ID protocol has been the most common protocol that allows alarm systems to communicate with central stations. When an alarm is triggered, the alarm panel taps the phone line and sends alarm signals to the central stations.
مع تغير التكنولوجيا، تتقادم خطوط النحاس وهذه الحل البديل سيكون VoIP.
مع ذلك، استبدال كامل للمحطات الأصلية بأخرى رقمية سيتطلب ميزانية كبيرة ويجلب مخاطر أكبر لتعطيل عملك. من الحكمة عدم تعديل لوحة إنذار الحريق والقيام فقط بترقية خطوط الاتصال. اتخاذ إجراء لاستبدال "خط النحاس القديم" بخط "لاسلكي" هو الحركة البسيطة وتجنب المتاعب.

لماذا لا يمكن للـ VoIP العمل مباشرة مع أنظمة إنذار الحريق؟
Most commercial fire alarm panels have two POTS lines connected to them. Each panel has a central station transmitter that uses POTS lines to send an alarm signal to the central stations when the alarm is triggered.
Unfortunately, when POTS lines are replaced with VoIP, alarm signals may become unrecognizable by central stations. Because VoIP converts analog signals to digital, the VoIP compression and decompression method can significantly affect the messages sent. Monitoring stations often stop receiving signals from the fire alarm panel. This is a common problem we must face.
Another note is power redundancy. When you lose electrical power, any device without battery redundancy becomes unusable. A traditional fire alarm system has dedicated battery redundancy, but standard VoIP systems do not have that. It is essential to integrate battery redundancy into our solution.

Now Flyingvoice provides a comprehensive solution for replacing POTS lines in a fire alarm system.
أولاً، نحن نوفر صندوق POTS التي تشمل صناعية راوتر LTE للوصول إلى الإنترنت، بنك طاقة للاحتياطي البطاري وت بوابة ATA للتعامل مع إشارة الإنذار الأصلية بشكل صحيح.
Paired with our cloud service to enhance alarm communications, delivery quality is guaranteed. The complete solution will comply with NFPA 72 (National Fire Alarm and Signaling Code).
توفير الخطوط والإعدادات إلى بوابة ATA، لا يلزم أي تغيير محدد على لوحة الإنذار، فقط قم بتمرير سلك النحاس من موصل RJ31x إلى مخارج هاتف بوابة ATA ثم سيعمل نظام الإنذار كالمعتاد.

For more details please refer to flyingvoice.com