Login web GUI, go into “FXS-->Preferences-->Miscellaneous” page, Enable Polarity Reversal
Application scenarios: Polarity (telephone line A, B line is positive and negative) reversed, as to when to reverse: 1. called off hook 2. the end of the call ,hang up.
Polarity reversal will produce a pulse, so the logger can record the user's call start time and end time to complete the valuation.
Test Method: You can use a multimeter to measure the polarity of the negative or vice versa from the off‑hook calls. The user port provides a voltage and the meter starts billing; the call ends and the user port provides a flip voltage, stopping billing.